Job calculator

Wall framing calculator

Enter the length and height of the wall, the stud spacing and the number of doors and windows. Plate rows, extra studs, header plies and opening widths are under Advanced. Counts only: lumber and header sizes come from your local code.

Measurements

Example values. Replace them with yours.

Read as 20 ft 0 in

ft-in

Read as 8 ft 0 in

ft-in

Example: 16 in

in

Example: 10%

%

Counts only: lumber sizes, header sizes and stud spacing are set by your local code. Studs are not taken out at openings; they become cripples.

Buy list

20 ft 0 in wall, 8 ft 0 in high

  1. 36
    studscut to 7 ft 7-1/2 in16 studs on spacing, 16 extra, plus 10% for cuts (Example).
  2. 5
    piecesplate stock, 16 ft 0 in3 rows along 20 ft 0 in.
  3. 2
    piecesdoor header, 3 ft 5 inSize set by your code and span.
  4. 4
    pieceswindow header, 3 ft 3 inSize set by your code and span.

Estimate only, not engineering advice. Values marked Example are not recommendations: adjust them to your local building code, permit requirements and the products you buy.

The working

  1. Stud length, wall less plates8 ft − 3 × 1.5 in = 7 ft 7-1/2 in
  2. Studs on spacing, plus one to close20 ft ÷ 16 in = 15 spaces, so 16 studs
  3. Extra studs at ends and openings2 × 2 + 3 × 4 = 16 studs
  4. Studs, plus 10% for cuts (Example), rounded up16 + 16 = 32; 32 × 1.1 = 35.2 → 36 studs
  5. Plate pieces, rounded up3 × 20 ft × 1.1 ÷ 16 ft = 4.13 → 5 pieces
  6. Door header pieces, opening plus a jack stud each side1 × 2 = 2 pieces, each 38 in + 2 × 1.5 in = 3 ft 5 in
  7. Window header pieces, opening plus a jack stud each side2 × 2 = 4 pieces, each 36 in + 2 × 1.5 in = 3 ft 3 in

Assumptions and sources

FigureUsedSourcePulled
Lumber thicknessActual thickness of a common 2 in board.1-1/2 inLowe's listing for 2-in x 4-in x 92-5/8-in Kiln-dried #2 Prime Stud, item 6003, model S204SE.1.92582026-11-17
Stud spacing16 inExample value, change it above as per design requirements.
Plate rows3Example value, change it under Advanced as per design requirements.
Extra studs at each end or corner2Example value, change it under Advanced as per design requirements.
Extra studs at each opening4Example value, change it under Advanced as per design requirements.
Header plies2Example value, change it under Advanced as per design requirements.
Door rough opening3 ft 2 inExample value, change it under Advanced as per design requirements.
Window rough opening3 ft 0 inExample value, change it under Advanced as per design requirements.
Plate stock length16 ft 0 inExample value, change it under Advanced as per design requirements.
Extra for cuts10%Example value, change it above as per design requirements.